請問一下我今天剛買這顆想當系統碟
是應該要先灌系統再刷韌體 還是 先更新韌體再灌系統呢?
小小疑問懇請大大們賜教
※ 引述《Shougon (光)》之銘言:
: http://www.crucial.com/support/firmware.aspx
: Version: 0309
: Release Date: 01/13/2012
: Change Log:
: ‧Changes made in version 0002 (m4 can be updated to revision 0309 directly
: from either revision 0001, 0002, or 0009)
: ‧Correct a condition where an incorrect response to a SMART counter will
: cause the m4 drive to become unresponsive after 5184 hours of Power-on time.
: The drive will recover after a power cycle, however, this failure will
: repeat once per hour after reaching this point. The condition will allow
: the end user to successfully update firmware, and poses no risk to user or
: system data stored on the drive.
: This firmware update is STRONGLY RECOMMENDED for drives in the field.
: Although the failure mode due to the SMART Power On Hours counter poses
: no risk to saved user data, the failure mode can become repetitive, and
: pose a nuisance to the end user. If the end user has not yet observed
: this failure mode, this update is required to prevent it from happening.
: If you are using a SAS Expander please do not download this Firmware.
: As soon as we have a Firmware Update that will work in these applications
: we will release it.
: 修復 5184 小時後開始 BSoD 的問題,就算目前沒問題的 user 一樣要 update。
--